Filtreler
Long-term effects of 900 MHz radiofrequency radiation emitted from mobile phone on testicular tissue and epididymal semen quality

Tas, M. | Dasdag, S. | Akdag, M.Z. | Cirit, U. | Yegin, K. | Seker, U. | Eren, L.B.

Article | 2014 | Electromagnetic Biology and Medicine33 ( 3 ) , pp.216 - 222

The purpose of this study is to bridge this gap by investigating effects of long term 900 MHz mobile phone exposure on reproductive organs of male rats. The study was carried out on 14 adult Wistar Albino rats by dividing them randomly into two groups (n: 7) as sham group and exposure group. Rats were exposed to 900 MHz radiofrequency (RF) radiation emitted from a GSM signal generator. Point, 1 g and 10 g specific absorption rate (SAR) levels of testis and prostate were found as 0.0623 W/kg, 0.0445 W/kg and 0.0373 W/kg, respectively. The rats in the exposure group were subject to RF radiation 3 h per day (7 d a week) for one year. F . . .or the sham group, the same procedure was applied, except the generator was turned off. At the end of the study, epididymal sperm concentration, progressive sperm motility, abnormal sperm rate, all-genital organs weights and testis histopathology were evaluated. Any differences were not observed in sperm motility and concentration (p > 0.05). However, the morphologically normal spermatozoa rates were found higher in the exposure group (p < 0.05). Although histological examination showed similarity in the seminiferous tubules diameters in both groups, tunica albuginea thickness and the Johnsen testicular biopsy score were found lower in the exposure group (p < 0.05, p < 0.0001). In conclusion, we claim that long-term exposure of 900 MHz RF radiation alter some reproductive parameters. However, more supporting evidence and research is definitely needed on this topic. © 2014 Informa Healthcare USA, Inc. All rights reserved: reproduction in whole or part not permitted Daha fazlası Daha az

Effect of long-term exposure of 2.4 GHz radiofrequency radiation emitted from Wi-Fi equipment on testes functions

Dasdag, S. | Taş, M. | Akdag, M.Z. | Yegin, K.

Article | 2015 | Electromagnetic Biology and Medicine34 ( 1 ) , pp.37 - 42

The aim of this study was to investigate long-term effects of radiofrequency radiation (RFR) emitted from a Wireless Fidelity (Wi-Fi) system on testes. The study was carried out on 16 Wistar Albino adult male rats by dividing them into two groups such as sham (n: 8) and exposure (n: 8). Rats in the exposure group were exposed to 2.4 GHz RFR radiation for 24 h/d during 12 months (1 year). The same procedure was applied to the rats in the sham control group except the Wi-Fi system was turned off. Immediately after the last exposure, rats were sacrificed and reproductive organs were removed. Motility (%), concentration (× 106/mL), tail . . . defects (%), head defects (%) and total morphologic defects (%) of sperms and weight of testes (g), left epididymis (g), prostate (g), seminal vesicles (g) were determined. Seminiferous tubules diameter (mm) and tunica albuginea thickness (µm) were also measured. However, the results were evaluated by using Johnsen's score. Head defects increased in the exposure group (p<0.05) while weight of the epididymis and seminal vesicles, seminiferous tubules diameter and tunica albuginea thickness were decreased in the exposure group (p<0.01, p<0.001, p<0.0001). However, other alterations of other parameters were not found significant (p?0.05). In conclusion, we observed that long-term exposure of 2.4 GHz RF emitted from Wi-Fi (2420 µW/kg, 1 g average) affects some of the reproductive parameters of male rats. We suggest Wi-Fi users to avoid long-term exposure of RF emissions from Wi-Fi equipment. © 2015 Informa Healthcare USA, Inc Daha fazlası Daha az

Signal detection theory approach to gastroesophageal reflux disease: A new method for symptom analysis of impedance-pH data

Giral, A. | Kurt, R. | Yegin, E.G. | Yegin, K.

Article | 2014 | Diseases of the Esophagus27 ( 3 ) , pp.206 - 213

An accurate reflux-symptom relationship analysis method is an unmet need in gastroesophageal reflux disease (GERD) diagnosis. The aim of this study was to adapt signal detection theory (SDT) approach to reflux-symptom relationship analysis to develop a new diagnosis method. Patients with predominant symptoms of heartburn and regurgitation were enrolled. Proton pump inhibitor (PPI)-responsive and PPI-unresponsive groups were created via interview and PPI trial. Patients then underwent stationary esophageal manometry and 24-hour multichannel intraluminal impedance-pH monitoring. SDT measurement parameters (discriminability: d' and cri . . .terion: c) were calculated using empirically selected time windows (0.5, 1, 2, 3, 4 and 5 minutes). The time window that provided the highest d' value was selected as the optimal time window. A cut-off d' value that optimally separates two groups was found using receiver operating characteristics analysis. Sixty-three patients completed the study (45 PPI responsive). Optimal time window and cut-off d' value were found as 1 and 0.767 minute, respectively. Symptom association probability (SAP) index values showed good correlation (rS = 0.7182, P < 0.0001) with d' values. SDT approach to reflux-symptom relationship analysis showed sensitivity (89% vs. 78%) and negative predictive values (75% vs. 60%) favorable over SAP index analysis. SDT approach using 1-minute time window and 0.767 cut-off d' value provides us a new and more accurate measure of reflux-symptom relationship than SAP index analysis. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus Daha fazlası Daha az

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms